PowerCom Macan MRT-2000 2000VA / 2000W MRT Series Online UPS – Rackmount

Features :-

  • Battery hot swappable design
  • Pure Sine Wave output with less than 2.5% THD
  • True double conversion
  • Diagram LCD display
  • UPSMON Pro and APP Support
  • 50/60Hz frequency converter mode
  • Power Factor 1.0 for Larger Power Density
  • Pure Sinewave Output with Double Conversion Topology
  • Extremely Low THD suitable for Delicate Instruments
  • Diagram LCD with Auto-Rotation for better User experience
  • Hot Swappable Battery Replacement for Maintenance
  • Overload, Surge, Short Circuit Protection
Capacity Capacity VA/W 1000/1000
Input Nominal Voltage 208V/220V/230V/240V
Voltage Range 120~140V under 25% load
140~160V under 50% load
160~180V under 75% load
180~276V under 100% load
Frequency 50Hz to 60Hz auto sensing
Output Voltage (on battery) 208V (derating 90%, 220V/230V/240V ±2% (selectable output voltage)
Frequency (on battery) 50Hz/60Hz ±0.25Hz
Wave form Pure sine wave
Transfer time 0ms
Overload recovery Auto transfer to UPS
Harmonic Distortion ≤ 2.5% THD at linear load
Normal efficiency mode (AC to AC) 90%
High efficiency mode (AC to AC) > 95%
Cress factor 3:1
Connections Standard IEC C13
Protection Surge Protection 230V (IEEE C61000-4-5 level 3)
Overload protection (on main) 105~120% for 30 seconds and 121~150% for 10 seconds
Overload protection (on battery) 101~109% for 10 seconds and 110~120% for 3 seconds
Short circuit protection UPS output cut off immediately or input fuse/circuit breaker protection
System/Display Warning Visual display Input/Output Voltage,
Input/output Frequency,
On-line mode,
Back-up mode,
Battery Capacity Level,
Load Level
Audible alarm (battery back-up) Beep every 5 seconds
UPS fault Continuous beeping sound and LCD display
Battery Type Sealed, maintenance-free lead acid battery
Typical recharge time 4 hours to 90%
Battery quantity 12V 7Ah x3
Management Self-test, adjustable battery transfer pointes and alarm settings
Battery protection Cut off without draining any current when battery is low
Cold start (DC start) Yes
Back up time (full load/half load) 2 to 4 mins/7 to 10 mins
General Input inlet IEC 320 (230V)
Receptacles IEC 320 (230V)
Communication interface RS-232 – USB B-type, Optional SNMP slot
Audible Noise < 45dBA(1m from surface)
Operation temperature 0 ~ 40°C
Storage temperature -20 ~ 50°C
Altitude 2000 meters max
Relative humidity 0-95%, non-condensing
Dimensions (mm) 428 (w) x 425 (d) x 84 (h)
Weight 15.8kg

PowerCom Macan MRT-2000 Data-sheet